Damper Repair for Brick Throats and Prefab Fireboxes
Ask About This Job
Name the fireplace type and what it is doing. A data plate model number, if you have it, lets us order the right part sooner.
Scope of the Job
In a factory-built fireplace the damper is a listed part of the box, with its own blade, spring and handle; when it fails we order the matching assembly. In a brick fireplace the cast plate rusts or warps, and the choice is to free it, replace it, or add a top-mounted damper worked by a cable. We confirm the choice suits your chimney before pricing it.
How dampers fail, brick and prefab
A damper lets you close the flue when the fireplace is cold. In a brick fireplace it is usually a cast plate on a frame set into the masonry above the firebox, worked by a handle, a rotary knob or a poker. In many factory-built units the damper is part of the box: a steel blade at the top of the firebox, opened by a pull handle, a lever or a chain, and listed along with the rest of the unit. Both fail in the same few ways. Rust from rain coming down the flue freezes the pivots or eats through the blade. Heat warps the plate until it no longer meets its seat. Linkages snap, and the small pins that join them work loose. Either fault costs you: a blade jammed closed makes a fire impossible, and one jammed partway lets the furnace's heat escape through the roof every night.
On a prefab unit, the repair follows the listing. Blades, springs, handles and chains are model specific, and we order them by the model on the firebox label. If the damper has rusted past saving, water has usually been getting into the unit for a while, so we look at the cap and chase lid for the cause and at the rest of the firebox for rust damage. On a brick fireplace, a damper that is only stiff can often be cleaned and freed. A warped or rusted plate in a frame that is still sound can sometimes be replaced as a plate. Once the frame itself has failed, a new throat assembly means chiseling out masonry, which is why many owners pick a damper mounted on the crown instead and leave the old opening clear.
Top sealing dampers and the written figure
A top sealing damper is a lid with a rubber seal, hinged on a frame fixed over the flue tile. Shut, nothing gets in from above, and warm room air stays below it. A stainless line runs down the flue to a bracket inside the firebox, where you work it. Owners like them because they seal far better than an old throat plate and keep the flue warm and dry. They are made for masonry flues, and some prefab makers offer a top damper approved for their own pipe; on prefab units that is the only kind we fit. Where a fireplace burns gas logs, any damper has to be blocked from closing fully while the gas is on, and we set that up as the log set manual requires.
Damper work is not on our published price list, since the fix ranges from freeing a stiff pivot to replacing a whole throat assembly. The written figure names the damper type, the part or model being fitted, any masonry work needed to get it in, and whether a cap change comes with it, since a top sealing damper often takes the place of the cap on that flue. On prefab units it names the maker's part. If the damper is fine and the trouble is elsewhere, for example smoke from a blocked cap or a short chimney rather than a closed blade, we tell you that. When you get in touch, say whether the handle moves, sticks or spins free; that tells us which parts to bring. Owners in Sherman Oaks and Burbank with older brick fireplaces book this most.
How Graves Chimney Experts Works
Data Plate First
The model is read before parts are named
Listed Parts
Panels, dampers and caps made for your unit
Price on Paper
Scope and figure written before work
Tested Before We Go
Draft, gas cycle or hose run on the repair
Where Graves Offers Chimney Damper Repair
Pick a city to read how the housing there changes this job.
That city is not on this list yet. The full city list is on the areas page.
Related Jobs
Chimney Sweep
Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.
Open this serviceChimney Inspection
NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.
Open this serviceChimney Repair
Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.
Open this serviceFireplace Inspection
A room-side check of the firebox, panels, screen, doors and hearth, read against the maker's listing for prefab units.
Open this serviceFireplace Repair
Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.
Open this serviceChimney Level 2 Inspection
Recorded video of the whole chimney pipe plus the chase and attic framing, for sales, fires, quakes and changed appliances.
Open this serviceChimney Cap Installation
Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.
Open this serviceChimney Flashing Repair
Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.
Open this serviceChimney Masonry Repair
Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.
Open this serviceChimney Rebuilds
Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.
Open this serviceFireplace Cleaning
Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.
Open this serviceGas Fireplace Cleaning
Burner, pilot, media and glass cleaned on sealed gas units, followed by a flame check and a carbon monoxide reading.
Open this serviceGas Fireplace Repair
Pilots that drop out, burners that stay dark and remotes that stopped answering, tested part by part before anything is ordered.
Open this serviceFireplace Remodel
New faces, hearths and mantels around prefab or brick fireboxes, built inside the clearances the unit's manual allows.
Open this serviceFireplace Inserts
Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.
Open this servicePellet Stove Repair
Pellet stoves that quit mid-burn or flash a fault code: motors, igniters, switches and boards tested before parts are ordered.
Open this serviceWood Stove Repair
Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.
Open this serviceGas Logs
Vented log sets for brick fireboxes and for prefab units listed to take them, piped, valved and lit before we leave.
Open this serviceChimney Seismic Retrofit
Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.
Open this serviceChimney Crown Repair
Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.
Open this serviceDryer Vent Cleaning
Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.
Open this serviceChimney Liner Installation
Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.
Open this serviceChimney Leak Repair
Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.
Open this serviceChimney Waterproofing
A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.
Open this serviceChimney Chase Cover
Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.
Open this service