A dimly lit historic parlor with a chandelier, wooden furniture, and two windows
Graves Chimney Experts

A Fireplace Inspection Built Around the Maker's Manual

Ask About This Job

Data Plate Read First
Listed Parts by Model
Written Scope Before Work
Based in Sherman Oaks
Data Plate Read First
Listed Parts by Model
Written Scope Before Work
Based in Sherman Oaks

Scope of the Job

Most fireplaces in tract houses built from the 1970s on are factory-built: a steel box lined with refractory panels, sold and tested as one system. We find the data plate, read the model, and check each part against what that listing allows. Cracked panels, a warped damper blade, missing screens, gaps at the hearth and trim set too close are noted with photos and a plain order of what to fix first.

Data plate located and model number recorded
Refractory panels examined for cracks, gaps and crumbling
Screen, glass doors and gaskets tried by hand
Hearth extension measured against the listing
Mantel and trim distances compared with the manual
Photos and a ranked list of findings

What we check inside a factory-built firebox

A prefab fireplace is a steel box inside another steel box, with an air space between them that keeps the outer shell cool enough to sit near the framing. Most of what goes wrong with it can be seen if you know where to look. Panels crack and then shed pieces, and once the steel behind them shows, the inner box takes direct flame it was never meant to take. The floor rusts where rain has come down the pipe, sometimes into a hole you can see through. The top of the box warps after years of oversized fires. Air slots at the base clog with ash. Grates get swapped for larger ones that push logs against the back panel. We check each of these, and we lift the lower grille to find the listing plate and confirm which model we are dealing with.

The second half of the inspection is everything around the unit. The manual for each model sets how close a wood mantel may sit above the opening, how near side trim can come, what facing may touch the front of the unit, and how far the hearth extension must reach out and to each side. Remodels change these. A new mantel goes up, stone is laid over the original surround, a raised hearth is built in front, and nobody checks the numbers. We measure what is there against the manual for your model, and where the manual is long gone, we work from the label and the maker's published data. Doors, screens, blowers and any gas line added later are looked at the same way: does this belong to this unit, and is it fitted as allowed?

Fireplace inspection or chimney inspection?

A fireplace inspection is the room side of the system: the unit and what surrounds it. It is the right visit when the question is about the box itself, such as a cracked panel you noticed while cleaning, a door that will not latch, smoke staining on the face above the opening, a new mantel you want to be sure about, or a buyer's inspector who flagged the fireplace and recommended a specialist. It is priced as a Level 1 at $57. When the question is about the pipe, the chase or the roof, a chimney inspection is the visit. And when something has happened that could have hurt hidden parts, such as a chimney fire, a strong quake or a switch from wood to gas, NFPA 211 points to a Level 2 at $410 with video of the whole run.

The report lists each item by where it is on the unit, what is wrong and what it means for using the fireplace, in one of three groups: do not light it until fixed, fix soon, or watch it. On prefab units many findings end with a part name or number, because the fix is usually a listed replacement rather than trade work. Panels, grates, door assemblies, screens and blower kits can often be ordered for models still supported. Where the maker no longer supplies a part, we say so up front instead of leaving you to find out later. If the fireplace passes, the report says so plainly and you can light it knowing what you have. Owners in Burbank and Santa Clarita often book this before the first cold week of the year.

How Graves Chimney Experts Works

Data Plate First

The model is read before parts are named

Listed Parts

Panels, dampers and caps made for your unit

Price on Paper

Scope and figure written before work

Tested Before We Go

Draft, gas cycle or hose run on the repair

Related Jobs

Chimney Sweep

Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.

Open this service

Chimney Inspection

NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.

Open this service

Chimney Repair

Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.

Open this service

Fireplace Repair

Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.

Open this service

Chimney Level 2 Inspection

Recorded video of the whole chimney pipe plus the chase and attic framing, for sales, fires, quakes and changed appliances.

Open this service

Chimney Cap Installation

Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.

Open this service

Chimney Flashing Repair

Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.

Open this service

Chimney Masonry Repair

Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.

Open this service

Chimney Rebuilds

Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.

Open this service

Fireplace Cleaning

Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.

Open this service

Gas Fireplace Cleaning

Burner, pilot, media and glass cleaned on sealed gas units, followed by a flame check and a carbon monoxide reading.

Open this service

Gas Fireplace Repair

Pilots that drop out, burners that stay dark and remotes that stopped answering, tested part by part before anything is ordered.

Open this service

Fireplace Remodel

New faces, hearths and mantels around prefab or brick fireboxes, built inside the clearances the unit's manual allows.

Open this service

Fireplace Inserts

Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.

Open this service

Pellet Stove Repair

Pellet stoves that quit mid-burn or flash a fault code: motors, igniters, switches and boards tested before parts are ordered.

Open this service

Wood Stove Repair

Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.

Open this service

Gas Logs

Vented log sets for brick fireboxes and for prefab units listed to take them, piped, valved and lit before we leave.

Open this service

Chimney Seismic Retrofit

Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.

Open this service

Chimney Crown Repair

Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.

Open this service

Dryer Vent Cleaning

Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.

Open this service

Chimney Liner Installation

Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.

Open this service

Chimney Leak Repair

Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.

Open this service

Chimney Waterproofing

A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.

Open this service

Chimney Damper Repair

Prefab damper blades, springs and handles refitted to the listing; brick fireplace dampers freed, replaced or moved to the top.

Open this service

Chimney Chase Cover

Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.

Open this service

Prefab fireplace guides by Graves Chimney Experts

Call (747) 224-9117