Remodeling Around a Factory-Built Fireplace Without Breaking Its Listing
Ask About This Job
Name the fireplace type and what it is doing. A data plate model number, if you have it, lets us order the right part sooner.
Scope of the Job
A prefab fireplace limits what can go around it: the manual sets how close a mantel can sit, what the face can be made of and where trim may touch the metal. We read those numbers first, then plan tile, stone or plaster to fit them. If the box itself should go, a gas insert for the opening you have runs $2,900 to $5,850, and a sealed gas unit framed into a new wall runs $4,700 to $9,400.
Start with the manual, not the mood board
Most remodel calls in Sherman Oaks and Calabasas begin with a picture of a fireplace the owner likes and a fireplace that looks nothing like it: a brass trimmed prefab opening from the 1980s with a tile surround and a boxy mantel. The look can change a great deal. What cannot change is what the unit's listing allows around it. Each model has a minimum height for a wood mantel above the opening, a distance side trim must keep, limits on facing materials that touch the front of the unit, and a hearth extension it needs. Some units allow stone or tile right up to the opening; others need a noncombustible band first. A heavy stone veneer may also need its own support rather than hanging from the framing. We read all of this before you choose finishes, so the design fits the box.
Sometimes the right remodel includes the unit itself. If the panels are cracked, the floor has rusted or the model is old enough that parts are scarce, it can make sense to pull the old firebox and set a new factory-built unit into the same framing, or fit a gas insert listed for the old box. Changing the unit also changes what the opening can look like: larger glass, a linear burner, a cleaner face. A new unit has to come with its own pipe and termination, which changes the roof side of the job, and on some swaps the framing must be adjusted to the new unit's clearances. We plan both ends together, so the room and the roof are opened once and the cap on top belongs to the box below.
Brick fireplaces, and what the scope includes
Older brick fireplaces can be remodeled too, and they are more forgiving about facing materials because the masonry itself does not burn. The limits there are how deep the hearth runs in front of the opening, how far a wood mantel has to stay from it, and the condition of the firebox behind the new face. Covering a firebox with cracked brick or failed joints in new stone does not fix it, so we inspect the box and the smoke chamber before the design is final. Where the fireplace is being converted to gas at the same time, the gas line and the choice of logs or insert are part of the plan from the start rather than added after the tile is set. Doing it in that order avoids cutting new stone to run a line.
The written scope for a remodel lists each part: removal of the old face and how dust is contained, any unit or insert being fitted, framing changes, the new surround and hearth material, the mantel, and the gas or electrical work involved. It names the clearances we are building to and where they come from. Finish materials you are supplying are noted, so it is clear who brings what. Design choices stay yours. Our part is to tell you what the unit allows, build the parts that touch it, and make sure the finished fireplace still matches the label on its side. Where tile or stone setting goes to a separate trade, they get the clearance numbers in writing. If the remodel comes before a sale, a Level 2 afterward gives the next owner a record that the work stayed inside the listing.
How Graves Chimney Experts Works
Data Plate First
The model is read before parts are named
Listed Parts
Panels, dampers and caps made for your unit
Price on Paper
Scope and figure written before work
Tested Before We Go
Draft, gas cycle or hose run on the repair
Where Graves Offers Fireplace Remodel
Pick a city to read how the housing there changes this job.
CA
Fireplace Remodel in Sherman Oaks
Two systems share these streets: the single brick chimney of a postwar tract house, and the factory-built or gas unit inside many apartment and condo buildings. We name which one you have before any part is ordered, since a metal box is repaired to its maker's listing.
Open city pageCA
Fireplace Remodel in Burbank
Aviation and film work drove a 1930s to 1950s building run, and 72% of homes are older than 1980, mostly on masonry flues. A gas log set in one of those boxes gets checked against what the firebox allows: damper clamp, venting, burner size.
Open city pageCA
Fireplace Remodel in Calabasas
Only 1% of homes predate 1950, and the planned tracts and gated streets mostly went up after 1970. Our first step is reading the firebox data plate, so a factory-built unit gets listed parts and a masonry one gets masonry repair.
Open city pageCA
Fireplace Remodel in Santa Clarita
Only 31% of homes predate 1980, and a tract here usually means a factory-built metal firebox, flue and cap, which age on their own terms rather than like brick. We replace chase tops, caps and panels with parts listed for that model, never generic sheet metal.
Open city pageRelated Jobs
Chimney Sweep
Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.
Open this serviceChimney Inspection
NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.
Open this serviceChimney Repair
Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.
Open this serviceFireplace Inspection
A room-side check of the firebox, panels, screen, doors and hearth, read against the maker's listing for prefab units.
Open this serviceFireplace Repair
Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.
Open this serviceChimney Level 2 Inspection
Recorded video of the whole chimney pipe plus the chase and attic framing, for sales, fires, quakes and changed appliances.
Open this serviceChimney Cap Installation
Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.
Open this serviceChimney Flashing Repair
Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.
Open this serviceChimney Masonry Repair
Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.
Open this serviceChimney Rebuilds
Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.
Open this serviceFireplace Cleaning
Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.
Open this serviceGas Fireplace Cleaning
Burner, pilot, media and glass cleaned on sealed gas units, followed by a flame check and a carbon monoxide reading.
Open this serviceGas Fireplace Repair
Pilots that drop out, burners that stay dark and remotes that stopped answering, tested part by part before anything is ordered.
Open this serviceFireplace Inserts
Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.
Open this servicePellet Stove Repair
Pellet stoves that quit mid-burn or flash a fault code: motors, igniters, switches and boards tested before parts are ordered.
Open this serviceWood Stove Repair
Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.
Open this serviceGas Logs
Vented log sets for brick fireboxes and for prefab units listed to take them, piped, valved and lit before we leave.
Open this serviceChimney Seismic Retrofit
Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.
Open this serviceChimney Crown Repair
Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.
Open this serviceDryer Vent Cleaning
Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.
Open this serviceChimney Liner Installation
Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.
Open this serviceChimney Leak Repair
Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.
Open this serviceChimney Waterproofing
A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.
Open this serviceChimney Damper Repair
Prefab damper blades, springs and handles refitted to the listing; brick fireplace dampers freed, replaced or moved to the top.
Open this serviceChimney Chase Cover
Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.
Open this service