Ask About This Job
Name the fireplace type and what it is doing. A data plate model number, if you have it, lets us order the right part sooner.
Scope of the Job
Gas fireplaces in prefab boxes use a small set of parts: valve, pilot, thermocouple or thermopile, igniter, receiver and switch. We test each with a meter and read the gas pressure before ordering, then order by the model on the data plate. After the swap we cycle the unit, leak-test every joint we touched and take a CO reading in the room.
The faults that bring us out
The calls follow a pattern. Nothing happens at all when the pilot is tried. The pilot catches, then goes dark when your hand comes off the control. The pilot burns but the burner ignores the switch or the remote. The burner lights late with a puff, or runs with a tall, dirty flame. The unit shuts itself off a few minutes into a burn. Each of those points to a short list of parts. On a standing pilot unit, the pilot flame heats a sensor that keeps the gas valve open, and if the sensor is worn or the flame is weak and off center, the valve closes. A second sensor makes the small current for the switch circuit, and a weak one gives a burner that will not answer. Units with electronic ignition add a control module, a spark electrode and often a flame rod that has to stay clean for the gas to keep flowing.
Guessing gets expensive on a gas valve, so the diagnosis comes first. We measure gas pressure at the valve, test the sensors with a meter, clean the pilot and check its position, and trace the wiring from the switch or receiver. On a sealed unit we look at the vent as well, because a blocked or separated vent pipe trips a safety and shuts the unit down, and that is a vent repair rather than a valve repair. Once the failed part is known, we read the model from the rating plate and order the maker's replacement. Universal parts exist for some components, but on a listed appliance we fit the maker's part wherever it is still supplied. A gas smell changes the order of things: everyone outside, the gas company called from there, and our visit after they have cleared the house.
Prefab gas units, inserts and log sets
In the Valley a gas fireplace is usually one of three things. A factory-built direct vent unit, often put in when a 1980s or 1990s house was built, with its own sealed box and a vent through the wall or roof. A gas insert set into an older wood fireplace, venting through liner pipe inside the old flue. Or a log set burning in an open firebox with the damper clamped so it cannot shut. Each has its own repair profile. Direct vent units mostly fail at the ignition parts and the glass gasket. Inserts add a blower and a liner connection to the list. Log sets are simpler, but they depend on the damper and the flue being open and sound, so a log set that smokes is often a chimney problem rather than a burner problem. We sort out which you have before talking about parts.
Repairs are given to you as a written figure once the fault is found and the part identified, so the cost of the part and the labor are known before anything is ordered. Some older units outlive their parts supply. When the valve or ignition module for yours has been discontinued, you hear that straight away, along with whether an approved substitute exists and, if not, what a new unit or insert would involve. On our price list, a gas insert set into a working firebox is $2,900 to $5,850, and a direct vent unit added to a room that has never had a fireplace is $4,700 to $9,400. Most visits do not end there, though. A cleaned pilot, a new sensor or a replaced receiver gets most units across Sherman Oaks and Calabasas running again for years.
How Graves Chimney Experts Works
Data Plate First
The model is read before parts are named
Listed Parts
Panels, dampers and caps made for your unit
Price on Paper
Scope and figure written before work
Tested Before We Go
Draft, gas cycle or hose run on the repair
Where Graves Offers Gas Fireplace Repair
Pick a city to read how the housing there changes this job.
CA
Gas Fireplace Repair in Sherman Oaks
Two systems share these streets: the single brick chimney of a postwar tract house, and the factory-built or gas unit inside many apartment and condo buildings. We name which one you have before any part is ordered, since a metal box is repaired to its maker's listing.
Open city pageCA
Gas Fireplace Repair in Burbank
Aviation and film work drove a 1930s to 1950s building run, and 72% of homes are older than 1980, mostly on masonry flues. A gas log set in one of those boxes gets checked against what the firebox allows: damper clamp, venting, burner size.
Open city pageCA
Gas Fireplace Repair in Calabasas
Only 1% of homes predate 1950, and the planned tracts and gated streets mostly went up after 1970. Our first step is reading the firebox data plate, so a factory-built unit gets listed parts and a masonry one gets masonry repair.
Open city pageCA
Gas Fireplace Repair in Santa Clarita
Only 31% of homes predate 1980, and a tract here usually means a factory-built metal firebox, flue and cap, which age on their own terms rather than like brick. We replace chase tops, caps and panels with parts listed for that model, never generic sheet metal.
Open city pageRelated Jobs
Chimney Sweep
Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.
Open this serviceChimney Inspection
NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.
Open this serviceChimney Repair
Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.
Open this serviceFireplace Inspection
A room-side check of the firebox, panels, screen, doors and hearth, read against the maker's listing for prefab units.
Open this serviceFireplace Repair
Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.
Open this serviceChimney Level 2 Inspection
Recorded video of the whole chimney pipe plus the chase and attic framing, for sales, fires, quakes and changed appliances.
Open this serviceChimney Cap Installation
Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.
Open this serviceChimney Flashing Repair
Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.
Open this serviceChimney Masonry Repair
Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.
Open this serviceChimney Rebuilds
Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.
Open this serviceFireplace Cleaning
Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.
Open this serviceGas Fireplace Cleaning
Burner, pilot, media and glass cleaned on sealed gas units, followed by a flame check and a carbon monoxide reading.
Open this serviceFireplace Remodel
New faces, hearths and mantels around prefab or brick fireboxes, built inside the clearances the unit's manual allows.
Open this serviceFireplace Inserts
Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.
Open this servicePellet Stove Repair
Pellet stoves that quit mid-burn or flash a fault code: motors, igniters, switches and boards tested before parts are ordered.
Open this serviceWood Stove Repair
Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.
Open this serviceGas Logs
Vented log sets for brick fireboxes and for prefab units listed to take them, piped, valved and lit before we leave.
Open this serviceChimney Seismic Retrofit
Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.
Open this serviceChimney Crown Repair
Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.
Open this serviceDryer Vent Cleaning
Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.
Open this serviceChimney Liner Installation
Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.
Open this serviceChimney Leak Repair
Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.
Open this serviceChimney Waterproofing
A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.
Open this serviceChimney Damper Repair
Prefab damper blades, springs and handles refitted to the listing; brick fireplace dampers freed, replaced or moved to the top.
Open this serviceChimney Chase Cover
Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.
Open this service