Level 2 Inspection for Prefab Pipe Runs and Brick Flues
Ask About This Job
Name the fireplace type and what it is doing. A data plate model number, if you have it, lets us order the right part sooner.
Scope of the Job
On a prefab system the worst problems sit where nobody looks: a pipe joint that has pulled apart inside the chase, a spacer missing in the attic, scorch marks on framing. The Level 2 is $410. We run a camera through the pipe, use the access points the house already has and record what we see. The report gives stills, where each finding sits and what it means for a buyer or owner.
When a look from the room is not enough
NFPA 211 ties the Level 2 to events, not to age: a house changing hands, a fireplace switched to gas or fitted with an insert, a chimney fire, a quake strong enough to crack plaster, or a performance problem nobody can explain from the firebox. Each of those can damage parts that a light and a mirror will not reach. In a factory-built chimney the pipe is made of short sections that twist and lock together, and a quake or a hard knock on the cap can pull a joint apart halfway up the chase. From the firebox the pipe looks fine. On camera the gap is plain to see, and so is the scorching on the outer wall if smoke has been leaking into the chase. That is the reason the level exists, and it is why we recommend it so often on Valley prefab chimneys.
Our Level 2 is $410. It includes everything in a Level 1, then a recorded camera pass up the whole run from the firebox to the termination, recorded so the footage can be looked at again later. Where the attic can be reached, we check the pipe where it passes through the ceiling: the firestop spacer should be there, the attic insulation shield should be in place, and nothing that burns should be touching the outer wall. On brick chimneys the same scan follows every tile joint looking for cracks, gaps and missing mortar, and the attic check is about clearance between the brick and the joists. The roof side covers the cap, the chase lid or crown, the flashing and the siding or upper brick. Each finding goes into the written report with a location, a plain description and how soon it matters.
Level 2 for a sale, a claim or a conversion
Most of our Level 2 bookings in Sherman Oaks, Burbank and Calabasas come out of escrow. A buyer's general inspector notes the fireplace, recommends a chimney specialist, and the contingency period is short. The report we write for that situation separates three things: safety items that stop the fireplace from being used, repairs that should be made, and normal wear. Buyer and seller negotiate from that list, so we keep the language plain and the locations exact. Copies go to whoever you list at booking, agents included. The home sale and agent pages cover how the visit is arranged around a listing, and the up to code page covers what happens after a Level 2 turns up repairs that have to be closed out before the deal does. The report is written to stand on its own in a transaction file.
Outside a sale, the two common triggers are a chimney fire and a fuel change. After a chimney fire, the inner wall of a metal pipe can buckle or discolor, and listed pipe that has been through a fire is generally treated as due for replacement; the scan shows how far the damage runs. Before a gas insert or gas logs go into a fireplace that burned wood for years, the Level 2 confirms the flue can take the new appliance and that its listing allows it. Insurance adjusters also ask for this level after a quake or a fire, because the recording shows the condition at a fixed point in time. Whatever the reason, the fee is the same, and the report uses plain words and photos, so a homeowner who stays on the ground can still follow each finding.
How Graves Chimney Experts Works
Data Plate First
The model is read before parts are named
Listed Parts
Panels, dampers and caps made for your unit
Price on Paper
Scope and figure written before work
Tested Before We Go
Draft, gas cycle or hose run on the repair
Where Graves Offers Chimney Level 2 Inspection
Pick a city to read how the housing there changes this job.
CA
Chimney Level 2 Inspection in Sherman Oaks
Two systems share these streets: the single brick chimney of a postwar tract house, and the factory-built or gas unit inside many apartment and condo buildings. We name which one you have before any part is ordered, since a metal box is repaired to its maker's listing.
Open city pageCA
Chimney Level 2 Inspection in Burbank
Aviation and film work drove a 1930s to 1950s building run, and 72% of homes are older than 1980, mostly on masonry flues. A gas log set in one of those boxes gets checked against what the firebox allows: damper clamp, venting, burner size.
Open city pageCA
Chimney Level 2 Inspection in Calabasas
Only 1% of homes predate 1950, and the planned tracts and gated streets mostly went up after 1970. Our first step is reading the firebox data plate, so a factory-built unit gets listed parts and a masonry one gets masonry repair.
Open city pageCA
Chimney Level 2 Inspection in Santa Clarita
Only 31% of homes predate 1980, and a tract here usually means a factory-built metal firebox, flue and cap, which age on their own terms rather than like brick. We replace chase tops, caps and panels with parts listed for that model, never generic sheet metal.
Open city pageRelated Jobs
Chimney Sweep
Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.
Open this serviceChimney Inspection
NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.
Open this serviceChimney Repair
Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.
Open this serviceFireplace Inspection
A room-side check of the firebox, panels, screen, doors and hearth, read against the maker's listing for prefab units.
Open this serviceFireplace Repair
Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.
Open this serviceChimney Cap Installation
Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.
Open this serviceChimney Flashing Repair
Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.
Open this serviceChimney Masonry Repair
Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.
Open this serviceChimney Rebuilds
Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.
Open this serviceFireplace Cleaning
Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.
Open this serviceGas Fireplace Cleaning
Burner, pilot, media and glass cleaned on sealed gas units, followed by a flame check and a carbon monoxide reading.
Open this serviceGas Fireplace Repair
Pilots that drop out, burners that stay dark and remotes that stopped answering, tested part by part before anything is ordered.
Open this serviceFireplace Remodel
New faces, hearths and mantels around prefab or brick fireboxes, built inside the clearances the unit's manual allows.
Open this serviceFireplace Inserts
Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.
Open this servicePellet Stove Repair
Pellet stoves that quit mid-burn or flash a fault code: motors, igniters, switches and boards tested before parts are ordered.
Open this serviceWood Stove Repair
Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.
Open this serviceGas Logs
Vented log sets for brick fireboxes and for prefab units listed to take them, piped, valved and lit before we leave.
Open this serviceChimney Seismic Retrofit
Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.
Open this serviceChimney Crown Repair
Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.
Open this serviceDryer Vent Cleaning
Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.
Open this serviceChimney Liner Installation
Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.
Open this serviceChimney Leak Repair
Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.
Open this serviceChimney Waterproofing
A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.
Open this serviceChimney Damper Repair
Prefab damper blades, springs and handles refitted to the listing; brick fireplace dampers freed, replaced or moved to the top.
Open this serviceChimney Chase Cover
Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.
Open this servicePrefab fireplace guides by Graves Chimney Experts
Escrow, rentals and failed reports: where Graves fits
Buyers, sellers, agents, managers and owners holding a failed Level 2 each need something different from a prefab fireplace visit. Pick the page written for your situation.
Home sale inspection
Get the chimney report inside the buyer's inspection window, in the right order.
For real estate agents
Three steps for agents: send the request, arrange access, name who gets the report.
Property managers and HOAs
One visit per building, $57 a fireplace for the visual check.
Up to code repairs
A failed Level 2, finding by finding, with the usual fix and our price where we have one.