Gas Log Sets for Wood Fireplaces, Checked Against the Listing
Ask About This Job
Name the fireplace type and what it is doing. A data plate model number, if you have it, lets us order the right part sooner.
Scope of the Job
Not every prefab fireplace may burn gas logs; the manual says whether it can and which kits are allowed. We check that first. Then we measure the box, choose a burner and log set that fit it, run the gas line with a valve you can reach, lock the damper partly open as the set requires, and light it with you watching. Sets are priced once you pick one.
Gas logs in a prefab firebox
Many factory-built wood fireplaces are listed to accept a decorative gas log set, and plenty of owners in the 1980s and 1990s houses here already have one. But the approval is specific. The fireplace manual usually says a vented log set may be used if it is listed for factory-built fireplaces, and some also cap the burner size or require the damper to be locked open. Vent free sets are a separate question, and many prefab fireplaces do not allow them at all. So we start by reading the fireplace label and manual, then choose a set whose own listing matches. The wrong kind of set in a prefab box is one of the items we write up most often during home sale inspections, and it is an avoidable one.
The rest of the choice is how it looks and how it fits. Sets come in widths matched to the firebox, with burners that give a deep bed of flame or a more open look, and with logs molded from ceramic fiber or refractory cement. Prefab boxes usually taper toward the back, so we size from the back wall and the depth as much as from the opening, and pick sets that leave room around the burner. Lighting can be by match, by a standing pilot with a remote, or by electronic ignition. What you pay follows three things: which set, which ignition, and how far gas has to travel to reach the hearth. You get that as a written figure once you have looked at the options with us. In an older house with no gas at the hearth, the line run is often the larger cost.
Brick fireplaces, flues and the install
In a masonry fireplace the questions are about the chimney. Exhaust from a vented set leaves the same way wood smoke did, so the flue still has to be clear, the tile sound and the cap in place, and a clamp keeps the damper from closing while the gas is on. A chimney with a cracked liner or no cap is not ready for logs, even though gas burns without the soot and sparks of wood. We look at the firebox and flue before we recommend a set, and if repairs come first we say so and write them up on their own. Gas logs also suit owners in the Valley who want a fire on winter evenings without watching for South Coast AQMD no burn days, which cover wood and not gas.
Installation means running a gas line to the hearth if there is none, fitting a shutoff valve where it can be reached, connecting the burner, setting the logs and embers in the pattern from the manual, and leak testing every joint with the line under pressure. We then light the set, compare the flame height and color with the manual, and watch the draft to be sure exhaust goes up and not into the room. You keep the manual, know where the shutoff is and have been shown the controls. If the set goes into a prefab fireplace, we leave a note of the log set listing with the fireplace manual, so the next inspector can see straight away that the pairing is approved. Homes in Sherman Oaks and Burbank with old brick fireplaces are where this conversion comes up most.
How Graves Chimney Experts Works
Data Plate First
The model is read before parts are named
Listed Parts
Panels, dampers and caps made for your unit
Price on Paper
Scope and figure written before work
Tested Before We Go
Draft, gas cycle or hose run on the repair
Where Graves Offers Gas Logs
Pick a city to read how the housing there changes this job.
CA
Gas Logs in Sherman Oaks
Two systems share these streets: the single brick chimney of a postwar tract house, and the factory-built or gas unit inside many apartment and condo buildings. We name which one you have before any part is ordered, since a metal box is repaired to its maker's listing.
Open city pageCA
Gas Logs in Burbank
Aviation and film work drove a 1930s to 1950s building run, and 72% of homes are older than 1980, mostly on masonry flues. A gas log set in one of those boxes gets checked against what the firebox allows: damper clamp, venting, burner size.
Open city pageCA
Gas Logs in Calabasas
Only 1% of homes predate 1950, and the planned tracts and gated streets mostly went up after 1970. Our first step is reading the firebox data plate, so a factory-built unit gets listed parts and a masonry one gets masonry repair.
Open city pageCA
Gas Logs in Santa Clarita
Only 31% of homes predate 1980, and a tract here usually means a factory-built metal firebox, flue and cap, which age on their own terms rather than like brick. We replace chase tops, caps and panels with parts listed for that model, never generic sheet metal.
Open city pageRelated Jobs
Chimney Sweep
Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.
Open this serviceChimney Inspection
NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.
Open this serviceChimney Repair
Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.
Open this serviceFireplace Inspection
A room-side check of the firebox, panels, screen, doors and hearth, read against the maker's listing for prefab units.
Open this serviceFireplace Repair
Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.
Open this serviceChimney Level 2 Inspection
Recorded video of the whole chimney pipe plus the chase and attic framing, for sales, fires, quakes and changed appliances.
Open this serviceChimney Cap Installation
Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.
Open this serviceChimney Flashing Repair
Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.
Open this serviceChimney Masonry Repair
Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.
Open this serviceChimney Rebuilds
Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.
Open this serviceFireplace Cleaning
Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.
Open this serviceGas Fireplace Cleaning
Burner, pilot, media and glass cleaned on sealed gas units, followed by a flame check and a carbon monoxide reading.
Open this serviceGas Fireplace Repair
Pilots that drop out, burners that stay dark and remotes that stopped answering, tested part by part before anything is ordered.
Open this serviceFireplace Remodel
New faces, hearths and mantels around prefab or brick fireboxes, built inside the clearances the unit's manual allows.
Open this serviceFireplace Inserts
Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.
Open this servicePellet Stove Repair
Pellet stoves that quit mid-burn or flash a fault code: motors, igniters, switches and boards tested before parts are ordered.
Open this serviceWood Stove Repair
Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.
Open this serviceChimney Seismic Retrofit
Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.
Open this serviceChimney Crown Repair
Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.
Open this serviceDryer Vent Cleaning
Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.
Open this serviceChimney Liner Installation
Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.
Open this serviceChimney Leak Repair
Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.
Open this serviceChimney Waterproofing
A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.
Open this serviceChimney Damper Repair
Prefab damper blades, springs and handles refitted to the listing; brick fireplace dampers freed, replaced or moved to the top.
Open this serviceChimney Chase Cover
Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.
Open this service