Graves Chimney Experts

Gas Fireplace Cleaning for Sealed Units and Log Sets

Ask About This Job

Data Plate Read First
Listed Parts by Model
Written Scope Before Work
Based in Sherman Oaks
Data Plate Read First
Listed Parts by Model
Written Scope Before Work
Based in Sherman Oaks

Scope of the Job

Sealed gas units collect lint, spider webs and a white film on the glass. With the gas valve off, we take the front off, lift out the logs or glass media, clear the burner ports and pilot hood, and wipe the glass with a cleaner made for it. The media goes back per the manual, then we relight, watch the flame and read CO in the room.

Front panel and glass removed with the valve shut
Lint cleared from burner ports and pilot hood
Logs, rocks or glass media laid back per the manual
White film taken off the glass
CO reading in the room after relighting

What builds up in a gas unit

Gas makes no ash, but the fireplace is not clean inside. A sealed direct vent unit takes its air from outdoors and sends its exhaust back out through a pipe in the wall or roof, and over a few seasons the glass takes on a white or gray film, dust and pet hair settle on the logs and burner, spiders build in the pilot hood, and the vent cap outside collects leaves or a nest. A log set in an open fireplace has its own version: soot on logs that have shifted out of place, burner ports half blocked with debris, and ember material pushed around until it covers the burner. Any of these changes how the flame burns. When the flame turns tall and orange and starts marking the logs black, the air and gas are no longer mixing the way the maker set them up.

The manual for each unit sets the order of work, and we keep to it. Nothing is opened until the valve is closed and the box is cool to the hand. Then the frame holding the glass unlatches and lifts away, the logs come off in the sequence the diagram shows, and the burner, pilot assembly and air shutter are cleared with brushes and low pressure air. The film on the glass is baked on, so it gets a cleaner that will not etch the surface. Logs are brushed and set back in the exact position in the diagram, because a log out of place sits in the flame and soots. The gasket around the glass frame is checked before the frame goes back, since a poor seal on a sealed unit lets exhaust into the room.

The checks that come with the cleaning

Once the unit is clean and back together, we light it and watch it run. The pilot should be a steady blue flame wrapping the sensor at its tip, and the main burner should light quickly and evenly along its length. We compare flame height with what the manual describes, and on a sealed unit we check that the vent cap outside is clear and has not been crushed or painted over. In the room, the space in front of the glass needs a working barrier. Units built in roughly the last decade ship with a screen, and older units without one can often take a retrofit screen from the same maker. We also try the remote or wall switch, and the receiver batteries get swapped if they look tired.

Some findings during a cleaning are repairs: a pilot that lights but will not hold, a burner that lights late with a soft bang, a glass panel cracked or chipped at the edge, a gasket gone brittle, or a vent cap outside dented by a roofer. We name each one and say whether it can be used in the meantime. Cracked glass on a sealed unit is a stop item, since the glass is part of the seal between the fire and the room. Parts for most current models can be ordered from the model number on the rating plate, which on most units sits behind the lower louver or hangs on a chain beside the valve. The gas repair page covers what those fixes involve, and owners in Sherman Oaks and Burbank usually pair the two visits.

How Graves Chimney Experts Works

Data Plate First

The model is read before parts are named

Listed Parts

Panels, dampers and caps made for your unit

Price on Paper

Scope and figure written before work

Tested Before We Go

Draft, gas cycle or hose run on the repair

Related Jobs

Chimney Sweep

Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.

Open this service

Chimney Inspection

NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.

Open this service

Chimney Repair

Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.

Open this service

Fireplace Inspection

A room-side check of the firebox, panels, screen, doors and hearth, read against the maker's listing for prefab units.

Open this service

Fireplace Repair

Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.

Open this service

Chimney Level 2 Inspection

Recorded video of the whole chimney pipe plus the chase and attic framing, for sales, fires, quakes and changed appliances.

Open this service

Chimney Cap Installation

Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.

Open this service

Chimney Flashing Repair

Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.

Open this service

Chimney Masonry Repair

Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.

Open this service

Chimney Rebuilds

Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.

Open this service

Fireplace Cleaning

Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.

Open this service

Gas Fireplace Repair

Pilots that drop out, burners that stay dark and remotes that stopped answering, tested part by part before anything is ordered.

Open this service

Fireplace Remodel

New faces, hearths and mantels around prefab or brick fireboxes, built inside the clearances the unit's manual allows.

Open this service

Fireplace Inserts

Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.

Open this service

Pellet Stove Repair

Pellet stoves that quit mid-burn or flash a fault code: motors, igniters, switches and boards tested before parts are ordered.

Open this service

Wood Stove Repair

Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.

Open this service

Gas Logs

Vented log sets for brick fireboxes and for prefab units listed to take them, piped, valved and lit before we leave.

Open this service

Chimney Seismic Retrofit

Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.

Open this service

Chimney Crown Repair

Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.

Open this service

Dryer Vent Cleaning

Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.

Open this service

Chimney Liner Installation

Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.

Open this service

Chimney Leak Repair

Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.

Open this service

Chimney Waterproofing

A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.

Open this service

Chimney Damper Repair

Prefab damper blades, springs and handles refitted to the listing; brick fireplace dampers freed, replaced or moved to the top.

Open this service

Chimney Chase Cover

Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.

Open this service
Call (747) 224-9117