Ask About This Job
Name the fireplace type and what it is doing. A data plate model number, if you have it, lets us order the right part sooner.
Scope of the Job
A pellet stove is wired like an appliance, so we diagnose it like one. We note the fault code, clean out the ash that trips most sensors, then test the feed motor, igniter, blowers, pressure switch and board in turn. Parts are ordered by model and serial. After the repair we run a full start and shutdown and check the vent joints for leaks.
How a pellet stove fails
Pellet stoves are rarer in the Valley than gas fireplaces, but we find them in Santa Clarita and the canyon houses where owners want steady heat from a fuel they can stack in the garage. Inside the cabinet, pellets drop from the hopper onto a screw that turns on a timer and carries them to the burn pot. An igniter heats them until they catch. A draft blower creates the suction that feeds the fire air and sends the smoke outside, while a second blower moves room air across the hot box and back into the house. Switches and sensors watch the box temperature, the suction and the hopper lid, and kill the feed if any reading strays. Nearly every failure is one of those parts, or ash where it should not be.
Igniters burn out, and the stove then fails at start up with pellets piled cold in the pot. Clinker builds in the pot until air cannot reach the fuel, and the fire smothers. Fly ash packs the exhaust passages and the vent until the suction switch reads low, and the stove quits a few minutes into a burn. The feed screw jams on a long pellet or a lump of swollen fuel, the feed motor fails, or the hopper lid switch sits out of position, and the fire starves while the fans keep running. On newer stoves the error code on the display narrows this down, and we read it against the manual for your model. We clean the passages first, because a fair share of repair calls end with ash removal and no part at all.
Parts, vents and the written figure
Pellet stoves come from many makers, and the parts do not cross between them, so every repair starts with the model plate on the back or side of the stove. Igniters, motors, blowers, switches and boards are ordered by that model, or by an approved replacement where the maker has updated a part. We do not fit a universal blower that happens to bolt up, because a fan with different flow changes the burn the stove was tested with. The vent gets the same treatment. Pellet stoves use a specific vent pipe with sealed joints, and a run with more elbows and horizontal length than the manual permits, or one that ends too near a window or a door, will cause trouble whatever parts are fitted. We look at the vent on every repair and tell you if it is part of the problem.
Repairs come with a written figure once the fault is found: the part, the labor and any cleaning involved. Some older stoves outlive their parts supply. When the board or motor for yours has been discontinued, you hear that before money goes into the parts that can still be had. After a repair, we take the stove through a full start, a spell at each heat setting and a shutdown, watching the flame in the pot and the readings on the display, so a second fault does not surface the week after we leave. Pellet quality matters as well; a brand that leaves heavy clinker in the pot is worth mentioning when you book. Owners who burn through the season usually have the stove and its vent cleaned once a year, which heads off most of these calls.
How Graves Chimney Experts Works
Data Plate First
The model is read before parts are named
Listed Parts
Panels, dampers and caps made for your unit
Price on Paper
Scope and figure written before work
Tested Before We Go
Draft, gas cycle or hose run on the repair
Where Graves Offers Pellet Stove Repair
Pick a city to read how the housing there changes this job.
CA
Pellet Stove Repair in Sherman Oaks
Two systems share these streets: the single brick chimney of a postwar tract house, and the factory-built or gas unit inside many apartment and condo buildings. We name which one you have before any part is ordered, since a metal box is repaired to its maker's listing.
Open city pageCA
Pellet Stove Repair in Burbank
Aviation and film work drove a 1930s to 1950s building run, and 72% of homes are older than 1980, mostly on masonry flues. A gas log set in one of those boxes gets checked against what the firebox allows: damper clamp, venting, burner size.
Open city pageCA
Pellet Stove Repair in Calabasas
Only 1% of homes predate 1950, and the planned tracts and gated streets mostly went up after 1970. Our first step is reading the firebox data plate, so a factory-built unit gets listed parts and a masonry one gets masonry repair.
Open city pageCA
Pellet Stove Repair in Santa Clarita
Only 31% of homes predate 1980, and a tract here usually means a factory-built metal firebox, flue and cap, which age on their own terms rather than like brick. We replace chase tops, caps and panels with parts listed for that model, never generic sheet metal.
Open city pageRelated Jobs
Chimney Sweep
Brushing and vacuuming for listed metal chimney pipe and clay flues, with the cap lifted and the firebox left clean.
Open this serviceChimney Inspection
NFPA 211 Level 1, 2 or 3 inspections for prefab metal systems and brick chimneys, each written up with photos.
Open this serviceChimney Repair
Repairs to metal chimney pipe, chase framing and siding, and to brick stacks: tops, joints, spacers and caps.
Open this serviceFireplace Inspection
A room-side check of the firebox, panels, screen, doors and hearth, read against the maker's listing for prefab units.
Open this serviceFireplace Repair
Panel, damper, screen, door and grate repairs on prefab fireplaces, using parts listed for the model on the data plate.
Open this serviceChimney Level 2 Inspection
Recorded video of the whole chimney pipe plus the chase and attic framing, for sales, fires, quakes and changed appliances.
Open this serviceChimney Cap Installation
Caps listed for your metal chimney pipe or sized to a clay flue, measured on the roof and fastened against wind.
Open this serviceChimney Flashing Repair
Leaks at the roof line around a brick or framed chimney traced to the metal and resealed, with a cricket where needed.
Open this serviceChimney Masonry Repair
Brick stacks with sandy joints, chipped faces or white staining repointed and patched with brick and mortar that match.
Open this serviceChimney Rebuilds
Brick stacks cracked through or loose at the top taken down and rebuilt, or replaced with a framed chase and listed pipe.
Open this serviceFireplace Cleaning
Ash, soot and fallen debris cleared from the firebox, with prefab panels brushed gently so they are not scored.
Open this serviceGas Fireplace Cleaning
Burner, pilot, media and glass cleaned on sealed gas units, followed by a flame check and a carbon monoxide reading.
Open this serviceGas Fireplace Repair
Pilots that drop out, burners that stay dark and remotes that stopped answering, tested part by part before anything is ordered.
Open this serviceFireplace Remodel
New faces, hearths and mantels around prefab or brick fireboxes, built inside the clearances the unit's manual allows.
Open this serviceFireplace Inserts
Gas and wood inserts for brick fireplaces, plus a check of whether your prefab box is listed to accept one at all.
Open this serviceWood Stove Repair
Freestanding stoves with leaking door seals, sagging baffles, cracked brick or tired catalysts put back in order.
Open this serviceGas Logs
Vented log sets for brick fireboxes and for prefab units listed to take them, piped, valved and lit before we leave.
Open this serviceChimney Seismic Retrofit
Brick chimneys on wood-frame houses braced, strapped or cut down and topped with lighter framing, with options set out on paper.
Open this serviceChimney Crown Repair
Cracked or crumbling mortar tops on brick stacks sealed, or poured new with an overhang that sheds water.
Open this serviceDryer Vent Cleaning
Lint packed in the duct from dryer to outside wall or roof cleared, and the outside flap freed so it opens.
Open this serviceChimney Liner Installation
Stainless liners for brick flues with cracked tile or a new appliance, and listed pipe replacements for prefab chimneys.
Open this serviceChimney Leak Repair
Water at the ceiling, wall or firebox traced to the chase top, cap, flashing, siding or brick, then repaired at that point.
Open this serviceChimney Waterproofing
A breathable water repellent on brick and block chimneys, applied after joints, top and flashing are made sound.
Open this serviceChimney Damper Repair
Prefab damper blades, springs and handles refitted to the listing; brick fireplace dampers freed, replaced or moved to the top.
Open this serviceChimney Chase Cover
Rusted or dished metal tops on framed chases replaced with a custom-cut stainless top that sheds water off the edges.
Open this service